STRUCTURE, FUNCTION, & MAINTENANCE STANDARD ELECTRONIC CONTROL SYSTEM 12 1) Control method in each mode Mode A Matching point in mode A: Rated speed SJP08758 OR 08912 If the pump load increases and the pressure rises, the engine speed lowers. At this time, the controller lowers the pump discharge so that the engine speed will be near the full output point. If the pressure lowers, the controller increases the pump discharge so that the engine speed will be near the full output point. By repeating these operations, the controller con- stantly uses the engine near the full output point.
SJP08759 OR 08913 SJP08760 OR 08914 10-174 PC210/240-7K Model PC210-7K, PC240-7K Mode A 106.6 kW/1,900 rpm {143 HP/1,900 rpm}