STRUCTURE, FUNCTION, & MAINTENANCE STANDARD ELECTRONIC CONTROL SYSTEM 12 1) Auto-warm-up function After the engine is started, if the engine cooling water temperature is low, the engine speed is raised auto- matically to warm up the engine. Water temperature: Below 30°C. Engine speed: Max. 1,200 rpm Engine speed: Max. 1,200 rpm Operating condition (All) Operated Reset Engine speed: Any level 2) Overheat prevention function If the engine cooling water temperature rises too high during work, the pump load and engine speed are reduced to prevent overheating. This function is turned on when the water temperature rises above 95°C.
Operating condition Operation/Remedy Resetting condition Water temperature: Below 105°C Fuel control dial: Return to low idle posi- tion once. Under above condition, controller is set to condition before operation of function. (Manual reset) Water temperature: Above 105°C Work mode: Any mode Engine speed: Low idle Monitor alarm lamp: Lights up Alarm buzzer: Sounds Operating condition Operation/Remedy Resetting condition Water temperature: Above 102°C Work mode: Mode A, E, OR B Engine speed: Keep as is. Monitor alarm lamp: Lights up. Lower pump discharge. Water temperature: Below 102°C Under above condition, controller is set to condition before operation of function.
(Automatic reset) Operating condition Operation/Remedy Resetting condition Water temperature: Above 100°C Work mode: Mode A Engine speed: Keep as is. Lower pump discharge. Water temperature: Below 100°C Under above condition, controller is set to condition before operation of function. (Automatic reset) Operating condition Operation/Remedy Resetting condition Water temperature: Above 95°C Work mode: Travel Engine speed: Keep as is. Lower travel speed. Water temperature: Below 95°C Under above condition, controller is set to condition before operation of function. (Automatic reset) 10-184 PC210/240-7K Resetting condition (Any one) Auto Water temperature:
Above 30°C Auto-warm-up operation time: Min. 10 minutes Manual Fuel control dial: Kept at 70% of full level for 3 sec. or longer