STRUCTURE, FUNCTION, & MAINTENANCE STANDARD ELECTRONIC CONTROL SYSTEM 12 1) Pump control function during travel If the machine travels in a work mode other than mode A, the work mode and the engine speed are kept as they are and the pump absorption torque is increased. For details, see ENGINE/PUMP COMPOSITE CON- TROL FUNCTION. 1. Travel speed change function i) Manual change with travel speed switch If the travel speed switch is changed between Lo, ( Mi), and Hi, the governor/pump controller controls the pump capacity and motor capacity at each gear speed as shown at right to change the travel speed.
ii) Automatic change by engine speed If the engine speed is lowered to 1,500 rpm or less with the fuel control dial during travel; the travel speed does not change even if the travel speed switch is changed from Lo, ( Mi) to Hi, the travel speed changes to Mi level automati- cally if the travel speed has been Hi. iii) Automatic change by pump discharge pressure While the machine is traveling with the travel speed switch at Hi, if the load is increased because of an upslope ground, etc.
and the travel pressure keeps above 24.5 MPa {250 kg/cmІ} for 0.5 seconds, the travel motor capacity is changed automatically and the travel speed is lowered (to the Mi level) (The travel speed switch is kept at Hi, however). While the machine is travelling at Mi level, if the load is reduced on a flat or downslope ground, etc. and the travel pressure keeps below 14.7 MPa {150 kg/cmІ} for 0.5 seconds, the travel motor capacity is changed automatically and the travel speed is set to Hi again. : The "Mi" mode is on the multi-monitor specification machine only.
08928 10-188 PC210/240-7K Travel speed switch Lo (Low speed) ( Mi) (Mid- dle Speed) Hi (High speed) Pump capacity (%) 60 90 100 Motor capacity Max. Max. Min. Travel speed (km/ h) 3.0 4.1 5.5