STRUCTURE, FUNCTION, & MAINTENANCE STANDARD ELECTRONIC CONTROL SYSTEM 12 3) Pump pressure sensor 1. Sensor 2. Connector FUNCTION The pump pressure sensor is installed to the inlet cir- cuit of the control valve. It converts the pump dis- charge pressure into a voltage and transmits it to the governor/pump controller. OPERATION The oil pressure applied from the pressure intake part presses the diaphragm of the oil pressure sensor, the diaphragm is deformed. The gauge layer facing the diaphragm measures the deformation of the diaphragm by the change of its resistance, then converts the change of the resistance into a voltage and transmits it to the amplifier (voltage amplifier).
The amplifier amplifies the received voltage and transmits it to the governor/pump controller. Relationship between pressure P (MPa {kg/cmІ}) and output voltage (V) is as follows. V = 0.08 [0.008] x P + 0.5 SJP08774 OR 08930 10-192 PC210/240-7K