TESTING AND ADJUSTING STANDARD VALUE TABLE FOR CHASSIS RELATED PARTS PC210/240-7K 20-15 Applicable model PC240LC, 240NLC-7K Cate- gory Item Measurement Condition Unit Standard value P ermissible value Performance of hydraulic pump Discharge amount of hydraulic pump (A mode) • Pump speed:
At 2,050 rpm, PC current 310 mA Test pump Discharge Average Standard value Judgement discharge pressure of pressure for discharge standard lower Check point pressure other pump amount Q limit Q (MPa {kg/cm2}) (MPa {kg/cm2}) (MPa {kg/cm2}) (¶/min) (¶/min) P1+P2 As desired P1 P2 See graph See graph 2 ★ As far as possible, bring pump discharge pressure P1 and P2 as close as possible to the average pressure when measuring. The error is large near the point where the graph curves, so avoid measuring at this point.
★ When measuring with the pump mounted on the machine, if it is impossible to set the engine speed to the spec- ified speed with the fuel control dial, take the pump discharge amount and the engine speed at the point of measurement, and use them as a base for calculating the pump discharge amount at the specified speed. Check point Test pump discharge pressure (MPa {kg/cm2}) Discharge pressure of other pump (MPa {kg/cm2}) Average pressure (MPa {kg/cm2}) Standard value for discharge amount Q (¶/min) As desired P1 P2 P1+P2 2 See graph