Komatsu — INSPECTION AND ADJUSTMENT OF PUMP LS CONTROL CIRCUIT OIL PRESSURE(pc240lc/nlc)

TESTING AND ADJUSTINGINSPECTION AND ADJUSTMENT OF PUMP LS CONTROL CIRCUIT OIL PRES- 2) Fit fitting K2 and connect it with oil pressure gauge of hydraulic tester K1 . Use an oil pressure gauge with the ca- pacity of 5.9 MPa{60 kg/cm 2 }. Adjustment When LS differential pressure is not normal, ad- just it with LS valves (6) and (7). 1. Loosen lock nut (8) and adjust the pressure by tuning adjusting screw (9). If the adjusting screw is turned to the right, the differential pressure rises. If the adjusting screw is turned to the left, the differential pressure falls. Adjustment amount (LS differential pres- sure) per turn of adjusting screw: 1.3 MPa{13.3 kg/cm 2 } 3 Lock nut:

49–64 Nm{5–7 kgm} 3) Start the engine and keep it running until the hydraulic oil temperature rises to the operat- ing range. 4) Measure the oil pressure when the engine is running at high idling and the travel speed switch and travel lever are operated. If LS-EPC valve output pressure chang- es to the following values, the pressure is normal. 2. After the adjustment, confirm that LS differential pressure is normal, following the steps for mea- surement explained earlier. Note: Operate the travel control lever slightly to the extent that the PPC hydraulic oil pressure is turned ON.

(Stop the operation short of starting the machine) 5) Detach all the measurement tools after the measurement, and make sure that the machine is back to normal condition. 20-130 PC210/240-7K Travel Speed Travel Control Lever Hydraulic Pressure Lo Neutral Approx. 2.9 MPa {approx. 30 kg/cm2} Hi Fine control (Note) 0{0}