TESTING AND ADJUSTINGINSPECTION AND ADJUSTMENT OF PUMP LS CONTROL CIRCUIT OIL PRES- 5) Measure pump delivery pressure and LS pressure (actuator loaded pressure) together with the machine set at the follow- ing conditions and the engine running at high idling. Working mode: A mode Traveling speed: Hi All the control levers of the work equip- ment, swing and travel are kept in the NEUTRAL position and the travel control lever is kept at half stroke (one side of the track shoes idly rotates). Let the raised track shoe idly rotate, pay- ing enough attention to the surroundings for safety. Calculation of LS differential pressure:
LS differential pressure = Pump delivery pressure – LS pressure If LS differential pressure is in the follow- ing conditions, it is judged normal. 3) Start the engine and raise the track shoe to be measured with the work equipment. For measuring oil pressure in front cir- cuit: Right track shoe For measuring oil pressure in rear cir- cuit: Left track shoe 6) Detach all the measurement tools after the measurement, and make sure that the machine is back to normal condition. 3. Measurement of LS-EPC valve output pres- sure 1) Remove oil pressure measurement plug (5). k Provide a working area of sufficient space, as the raised track shoe will be idly rotated.
4) Wait until the hydraulic oil temperature rises to the operating range. PC210/240-7K 20-133 Control lever position LS differential pressure All levers in NEUTRAL Unload pressure (see standard value table) Travel lever at half stroke Max. LS differential pressure (see standard value table)