Komatsu — MEASUREMENT OF SOLENOID VALVE OUTPUT PRESSURE

TESTING AND ADJUSTING MEASUREMENT OF SOLENOID VALVE OUTPUT PRESSURE Table for Functioning Conditions - 2-stage relief solenoid valve Table for Functioning Conditions - Merge/divide solenoid valve : The "L" mode is on the multi-monitor specification machine only.

PC210/240-7K 20-137 Functioning Condition Functioning When overheat setting of the 1st stage is ON OFF When overheat setting of the 2nd stage is ON When all the signals for work equipment, swing and travel are OFF When swing lock switch is ON ON When travel signal is ON When working mode is L mode When boom LOWER signal is ON When working mode is A or E mode When left knob switch is ON If signals other than swing operation only is ON If swing operation only is ON OFF In conditions other than above Functioning Condition Functioning When working mode is B mode When service signal is ON ON When working mode is L mode When boom RAISE and swing signals are ON When travel signal only is ON When compound travel marks are ON When steering sig- nal is OFF If front or rear pump pressure is over 19.6 MPa (200 kg/cm2) When travel signal is OFF When swing lock switch is ON OFF When working mode is A mode When swing signal is ON When swing signal is OFF When service and arm dumping signal are ON If front or rear pump pressure is over 19.6 MPa{200 kg/cm2} ON In conditions other than above OFF