TESTING AND ADJUSTING INSPECTION PROCEDURES FOR DIODE INSPECTION PROCEDURES FOR DIODE Check an assembled-type diode (8 pins) and sin- gle diode (2 pins) in the following manner. The continuity direction of an assembled-type di- ode is as shown in the diagram below. The continuity direction of a single diode is shown on the diode surface. 3) Determine if a specific diode is good or no good with the indicated value. No change in the indicated value: No continuity (defective). Change in the indicated value: Continui- ty established (normal) (Note) Note: A silicon diode shows a value between 400 and 600. 2. When using analog type circuit tester 1) Switch the testing mode to resistance range.
2) Check the needle swing in case of the fol- lowing connections. i) Put the red probe (+) of the test lead to the anode (P) and the black probe (–) to the cathode (N) of diode. ii) Put the red probe (+) of the test lead to the cathode (N) and the black probe (–) to the anode of diode. 3) Determine if a specific diode is good or no good by the way the needle swings. If the needle does not swing in Case i), but swings in Case ii): Normal (but the breadth of swing (i.e. resistance value) will differ depending on a circuit tester type or a selected measurement range) If the needle swings in either case of i) and ii):
Defective (short-circuited inter- nally) If the needle does not swing in any case of i) and ii): Defective (short-circuited in- ternally) 1. When using digital type circuit tester 1) Switch the testing mode to diode range and confirm the indicated value. Voltage of the battery inside is displayed with conventional circuit testers. 2) Put the red probe (+) of the test lead to the anode (P) and the black probe (–) to the cathode (N) of diode, and confirm the dis- played value. 20-146 PC210/240-7K