TESTING AND ADJUSTING SPECIAL FUNCTION OF MULTI-MONITOR PANEL 9. Function for adjusting breaker and attach- ment flow rate (For machines equipped with breaker attachment) When a breaker or other attachments are used, hydraulic pump flow rate can be adjusted by operating the select switch. Note that the symbol mark and contents of display partially differ between the breaker and the other attachments. 10. Function for confirming maintenance infor- mation Detailed information on maintenance items (set time and elapse of time) can be confirmed and resetting after the confirmation is feasible by operating the maintenance switch.
Use service Menu for setting or releasing maintenance items and setting maintenance time. 11. Function for showing service meter reading Only the service meter reading can be shown by the following switching operation, when the engine starting switch is turned OFF. Switching operation: [ ] + [ ] (synchro- nized switching operation) 12. Function for checking display LCD Display of the Display LCD can be confirmed by the following switching operation in the display of inputting and setting password as well as in the display of ordinary items Switching operation: [ ] + [A] (synchro- nized switching operation) All the LCD light up, turning the entire screen white.
If there is no showing in black, the dis- play is normal. This display returns to the immediately pre- ceding one, if making any other switching operation. PC210/240-7K 20-151