TESTING AND ADJUSTING SPECIAL FUNCTION OF MULTI-MONITOR PANEL 4) Set contents of individual items : Default: The maintenance time set in the monitor (recommended by the man- ufacturer and cannot be changed). : Set: Maintenance time that can be freely set. The maintenance mode pro- gram functions based on this mainte- nance time. (The maintenance time can be increased or decreased by 50 hours with [ ] or [ ] switch) : On: Maintenance display function with this instruction becomes effectual. : Off: Maintenance display with this instruction becomes ineffectual. The lowest maintenance time is 50 h.
5) Set contents of "Use Default Values" When selecting this menu and depressing the switch [ ], all individual time settings are reduced to the initial settings. PC210/240-7K 20-165