TESTING AND ADJUSTING E101 Service Code in Electrical System (Abnormal data in Error History) E101 20-306 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Abnormal data in the error history (in Monitor Panel system) — E101 DAF0KT Failure content • The voltage in the firm power source circuit for Monitor Panel (battery) has dropped below 12 V or exceeded 36 V. Response from Monitor Panel • None in particular Phenomenon occurring on machine • A display for information on the failure history (in the electrical system) cannot be called. Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Fuse No.
12 defective If the fuse is blown, there is a big possibility that the circuit has a grounding fault. 2 Fusible link No. A35 defective If the fusible link is blown, there is a big possibility that the circuit has a grounding fault. 3 Disconnection of wiring harness (Disconnection or connector contact fault) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position for the troubleshooting.
Wiring harness from P01 (female) to J07 to FB1-17 out- let Resistance value Above 1 Ω Wiring harness between FB1-17 inlet and A35 (male) Resistance value Above 1 Ω Wiring harness between A35 (male) and A23 (B termi- nal) Resistance value Above 1 Ω 4 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position for the troubleshooting.
Between wiring harness between P01 (female) to J07 and FB1-17 outlet and grounding Resistance value Above 1 MΩ Between wiring harness between FB1-17 inlet and A35 (male) and grounding Resistance value Above 1 MΩ Between wiring harness between A35 (male) and A23 (B terminal) and grounding Resistance value Above 1 MΩ 5 Monitor Panel defective ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position for the troubleshooting. C03 Voltage Between and 20 – 30 V