TESTING AND ADJUSTING E113 Service Code in Electrical System (Short-circuiting in reverse rotation system of windshield wiper motor drive) E113 20-310 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Short-circuiting in reverse rotation system of wind- shield wiper motor drive (in Monitor Panel system) — E113 DY2EKB Failure content • Abnormal current flew to the reverse rotation circuit of the windshield wiper motor drive, when the windshield wiper was set in motion. Response from Monitor Panel • Power supply to the reverse rotation circuit of the windshield wiper motor drive was switched OFF. Phenomenon occurring on machine • The windshield wiper stopped moving.
Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Windshield wiper motor defective (Internal short-circuiting or grounding fault) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position for the troubleshooting. W04 (female) Continuity and resistance value Between and Continued Between and grounding Above 1 MΩ 2 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position for the troubleshooting.
Between wiring harness between P01 (female) and W04 (male) and grounding Resistance value Above 1 MΩ 3 Monitor panel defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position for the troubleshooting. P01 Windshield wiper switch Voltage Between and grounding OFF Below 3 V ON Below 3 V⇔20 – 30 V (at constant cycle)