Komatsu — Service Code in Electrical System (Short-circuiting in travel interlocking solenoid)

TESTING AND ADJUSTING E116 Service Code in Electrical System (Abnormality in retracting windshield wiper) E116 20-316 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Abnormal operation of retracting windshield wiper (in Monitor Panel system) — E116 DY20MA Failure content • P signal in the retraction range is not inputted, when the wiper is retracted. Response from Monitor Panel • Power supply to the windshield wiper motor is switched OFF, when the wiper is retracted. Phenomenon occurring on machine • The windshield wiper cannot be retracted completely.

Relative information • It can be checked in the monitoring function whether P signal (ON or OFF) in the retraction operation range is inputted or not. (Code No. 049: Monitor Input 3) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Windshield wiper motor defective (Internal disconnection) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position for the troubleshooting.

W04 (female) Windshield wiper blade Resistance value Between and Retraction range Below 1 Ω Operation range Above 1 MΩ 2 Disconnection of wiring harness (Disconnection or defec- tive contact with connec- tor) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Wiring harness between P01 (female) and W04 (male) Resistance value Below 1 Ω Between wiring harness W04 (male) and grounding Resistance value Below 1 Ω 3 Monitor panel defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.

P01 Windshield wiper blade Voltage Between and grounding Retraction range Below 1V Operation range 20 – 30 V