Komatsu — Service Code in Electrical System (Short-circuiting in travel speed shifting solenoid)

TESTING AND ADJUSTING E206 Service Code in Electrical System (Short-circuiting in travel speed shifting solenoid) E206 20-326 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Short-circuiting in travel speed shifting solenoid (in governor • pump controller system) — E206 DW43KB Failure content • Abnormal current flew to the travel speed shifting solenoid, when power was supplied to the circuit. Response from controller • Power supply to the travel speed shifting solenoid circuit is switched OFF. • Even after the failure cause disappears of itself, the machine operation does not return to normalcy, unless the engine starting switch is once turned OFF.

Phenomenon occurring on machine • The travel speed does not turn to Hi. (The display in the monitor panel changes correctly) Relative information • Operation of the travel speed shifting solenoid (ON or OFF) can be checked in the monitoring function. (Code No. 023: Solenoid 1) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Travel speed shifting solenoid defective (Internal short-circuiting or grounding fault) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

V04 (male) Resistance value Between and 20 – 60 Ω Between and grounding Above 1 MΩ 2 Assembled-type diode D04 defective (Internal short-circuiting) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. D04 (male) Resistance value Between and Above 1 MΩ 3 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Wiring harness from C03 (female) to J06 to V04 (female) , or between wiring harness between C03 (female) and D04 (female) and grounding Resistance value Above 1 MΩ 4 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it running during the troubleshooting. C03 Travel speed Voltage Between and grounding Lo Below 1 V Hi + Travel operation 20 – 30 V