Komatsu — Service Code in Electrical System (Disconnection in travel interlocking solenoid)

TESTING AND ADJUSTING E211 Service Code in Electrical System (Disconnection in travel interlocking solenoid) E211 20-328 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Disconnection in travel interlocking solenoid (in governor • pump controller system) — E211 DW91KA Failure content • No current flows to the travel interlocking solenoid circuit, when power is supplied to the circuit. Response from controller • None in particular (The solenoid does not function as there is current flowing to it) • When the failure cause disappears of itself, the machine operation returns to normalcy. Phenomenon occurring on machine • It is difficult to steer the machine while traveling.

Relative information • Operation of the travel interlocking solenoid (ON or OFF) can be checked in the monitoring function. (Code No. 023: Solenoid 1) ★The solenoid detects disconnection, when power is ON. Hence be sure to check it with power ON after the repairs. (For how to turn power ON or OFF, refer to the troubleshooting under Service Code [E201].) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Travel interlocking solenoid defective (Internal disconnection) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

V02 (male) Resistance value Between and 20 – 60 Ω 2 Disconnection of wiring harness (Disconnection or defec- tive contact with connec- tor) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Wiring harness from C03 (female) to J06 to V02 (female) Resistance value Below 1 Ω Wiring harness between V02 (female) and grounding Resistance value Below 1 Ω 3 Short-circuiting of wiring harness (Contact with 24 V cir- cuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.

Wiring harness from C03 (female) to J06 to V02 (female) , or between wiring harness C03 (female) and D03 (female) and grounding Voltage Below 1 V 4 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. C03 (female) Resistance value Between and grounding 20 – 60 Ω