Komatsu — Service Code in Electrical System Disconnection of S-NET signal)

TESTING AND ADJUSTING E217 Service Code in Electrical System (Abnormality in inputting model code) PC210-7K E217 20-338 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Abnormality in inputting model code (in governor • pump controller system) — E217 DA2SKQ Failure content • A model code signal was inputted which indicates another model that is not registered in the controller. Response from controller • The controller treats it as a default-set model (PC210). • Even if the failure cause disappears of itself, the machine operation does not return to normalcy, unless the engine starting switch is once turned OFF.

Phenomenon occurring on machine • None in particular with PC210 model Relative information • Model names (expressed in number) that the controller recognizes can be confirmed in the monitoring function. (Code No. 002 and 003: Controller Model Code) ★Input of model selecting signals (ON or OFF) can be confirmed in the monitoring function.(Code No. 027:Switch Input 2) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Model selecting connec- tor defective (Internal disconnection or short-circuiting) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

C09 (female) Resistance value Between and Below 1 Ω Between , , or and Above 1 MΩ 2 Disconnection of wiring harness (Disconnection or defec- tive contact with connec- tor) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Wiring harness between C03 (female) and C09 (male) Resistance value Below 1 Ω Between wiring harness between C09 (male) and J05 and grounding Resistance value Below 1 Ω 3 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Between wiring harness between C03 (female) and C09 (male) and grounding Resistance value Above 1 MΩ Between wiring harness between C03 (female) and C09 (male) and grounding Resistance value Above 1 MΩ Between wiring harness between C03 (female) and C09 (male) and grounding Resistance value Above 1 MΩ Between wiring harness between C03 (female) and C09 (male) and grounding Resistance value Above 1 MΩ 4 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting. C03 Voltage Between , , or and grounding 20 – 30 V Between and grounding Below 1 V