Komatsu — Service Code in Electrical System Disconnection of S-NET signal)

TESTING AND ADJUSTING E218 Service Code in Electrical System Disconnection of S-NET signal) E218 : The multi-monitor specification machine only. 20-342 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Disconnection in S-NET signal (in governor • pump controller system) — E218 DA2SKA Failure content • A failure occurred in S-NET communication between the monitor and controller in the past. (The machine operation returned to normalcy, when the display was resumed) Response from controller • While the failure is still continuing, the machine operation is controlled by the following default setting. 1) Working mode: E mode 2) Travel speed: Lo 3) Auto-decelerator:

ON 4) Attachment oil flow rate: Minimum ( ) • When the failure cause disappears of itself, the machine operation returns to normalcy. Phenomenon occurring on machine • The working mode cannot be changed. (The display changes normally in the monitor panel) • The travel speed cannot be shifted. (The display changes normally in the monitor panel) • The auto-decelerator cannot be released. (The display changes normally in the monitor panel) • The attachment oil flow rate cannot be changed. (The display changes normally in the monitor panel) ( ) Relative information • This Service Code No.

is displayed to inform that there was a failure occurred in the past, when S-NET communication between the monitor panel and the governor • pump controller is returned to normalcy. • The communication has already returned to normalcy by the time this Service Code No. is displayed. But thoroughly diagnose all the related equipment and circuits, and remove all potential causes for a failure in order to prevent recurrence of failures.

Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Disconnection of wiring harness (Disconnection or defec- tive contact with connec- tor) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Wiring harness between P02 (female) and C02 (female) Resistance value Below 1 Ω Wiring harness between P02 (female) and C02 (female) Resistance value Below 1 Ω 2 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Between wiring harness between P02 (female) and C02 (female) and grounding Resistance value Above 1 MΩ 3 Short-circuiting of wiring harness (Contact with 24 V cir- cuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting. Between wiring harness between P02 (female) and C02 (female) and grounding Voltage Below 1 V 4 Monitor panel defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.

P02 (male) Voltage Between and 6 – 9 V 5 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting. C02 (male) Voltage Between and 6 – 9 V