TESTING AND ADJUSTING E226 Service Code in Electrical System (Abnormality in Pressure sensor power source) E226 20-350 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Abnormality in pressure sensor power source (in governor • pump controller system) — E226 DA25KP Failure content • Abnormal current flew to the power source circuit (5 V) for the pressure sensors and potentiometer. Response from controller • The controller turns OFF power supply to the power source circuit (5 V). • Even when the failure cause disappears of itself, the current does not return to normalcy, unless the en- gine starting switch is once turned OFF.
Phenomenon occurring on machine • Signals from the pressure sensors and potentiometer are not inputted correctly. • The Service Code of "pressure sensor abnormal" and that of "potentiometer abnormal" are displayed at the same time. Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Pressure sensor or potentiometer defective (Internal short-circuit) Disconnect the following equipment one by one. Equipment that shows no service code is defective, having an internal failure. ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.
Fuel dial E06 Connector Governor motor potentiometer E10 Connector F pump pressure sensor A51 Connector R pump pressure sensor A52 Connector 2 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness from C01 (female) to J07 to E06 (female) and grounding [Fuel dial system] Resistance value Above 1 MΩ Between wiring harness from C01 (female) to J07 to E10 (female) and grounding [Governor potentiometer system] Resistance value Above 1 MΩ Between wiring harness from C01 (female) to J07 to A51 (female) and grounding [F pump pressure sensor system] Resistance value Above 1 MΩ Between wiring harness from C01 (female) to J07 to A52 (female) and grounding [R pump pressure sensor system] Resistance value Above 1 MΩ Between wiring harness from C01 (female) to J07 to A08 (male) and grounding [Attachment system] Resistance value Above 1 MΩ 3 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.
C01 Voltage Between and 4.5 – 5.5 V