TESTING AND ADJUSTING E238 Service Code in Electrical System (Disconnection in attachment return switching relay) E238 20-358 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Disconnection in attachment return switching relay (in governor • pump controller system) — E238 D196KA Failure content • When the attachment switching relay circuit is disconnected from grounding (power OFF), 24 V voltage is not generated. Response from controller • None in particular • If the failure cause disappears, the governor returns to normalcy.
Phenomenon occurring on machine • The hydraulic circuit for attachments cannot be switched to the single operation Relative information • It can be confirmed in the monitor function how the attachment return switching relay circuit works (ON or OFF). (Code No. 024:Solenoid 2) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Fuse No. 2 fault If the fuse has been blown, there is a big possibility that grounding fault occurred in the relay circuit.
2 Attachment return switching relay defective (Internal disconnection) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. R20 (male) Resistance value Between and 100 – 500 Ω 3 Emergency pump driving switch defective (Internal disconnection) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between C02 (female) and R20 (female) Resistance value Below 1 Ω Wiring harness from R20 (female) to J03 to FB1-2 outlet Resistance value Below 1 Ω 4 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between C02 (female) and R20 (female) and grounding Resistance value Above 1 MΩ Between wiring harness from R20 (female) to J03 to FB1-2 outlet and grounding Resistance value Above 1 MΩ 5 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting. C03 Working mode Voltage Between and grounding Other than B mode 20 – 30 V B mode Below 1 V