TESTING AND ADJUSTING E306 Service Code in Electrical System (Abnormality in governor potentiometer) E306 20-364 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Abnormality in governor potentiometer (in governor • pump controller) — E306 DK54KZ Failure content • Signal voltage from the governor potentiometer dropped below 0.4 V or exceeded 4.6 V. Response from controller • The controller exercises control by computing the motor position through voltage right before a failure occurred. • Even if the failure cause disappears of itself, the governor potentiometer does not return to normalcy, unless the engine starting switch is once turned OFF.
Phenomenon occurring on machine • The engine cannot attain the specified rotation at high idling. (A bit lower) • The engine cannot attain the specified rotation at low idling (A bit higher) • The auto-decelerator or automatic warming-up function does not work. • There is hunting while the engine is running. • The engine stalls. • The engine does not stop. Relative information • Input from the governor potentiometer (voltage) can be confirmed in the monitor function. (Code No. 031: Governor potentiometer voltage) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Sensor power source defective If Service Code No.
[E226] is displayed, troubleshoot the failure first. 2 Governor potentiometer defective (Internal failure) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. E10 (male) Resistance value Between and 4.0 – 6.0 kΩ Between and 0.25 – 5.0 kΩ Between and 0.25 – 5.0 kΩ 3 Disconnection of wiring harness (Disconnection or defec- tive contact with connec- tor) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C01 (female) to J07 to E10 (female) Resistance value Below 1 Ω Wiring harness between C01 (female) and E10 (female) Resistance value Below 1 Ω Wiring harness between C01 (female) and E10 (female) Resistance value Below 1 Ω 4 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between C01 (female) and E10 (female) and grounding Resistance value Above 1 MΩ 5 Short-circuiting of wiring harness (Contact with 24 V cir- cuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting. Between wiring harness from C01 (female) to J07 to E10 (female) and grounding Voltage Below 1 V Between wiring harness between C01 (female) and E10 (female) and grounding Voltage Below 1 V 6 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.
C01 Resistance value Between and 4.5 – 5.5 V Between and 0.5 – 4.5 V