TESTING AND ADJUSTING E308 Service Code in Electrical System (Abnormality in fuel dial) E308 20-366 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Abnormality in governor fuel dial (in governor • pump controller) E05 E308 DK10KZ Failure content • Signal voltage from the from fuel dropped below 0.23 V or exceeded 4.77 V. Response from controller • The controller exercises control by computing the fuel dial position through voltage right before a failure occurred. • If the failure cause disappears, the fuel dial returns to normalcy. Phenomenon occurring on machine • If the fuel dial had been set at FULL before a failure occurred, it does not change to PARTIAL.
• If the fuel dial had been set at PARTIALLY before a failure occurred, it does not change to FULL. • There is hunting while the engine is running. • The engine cannot attain the specified rotation at high idling and lacks power. Relative information • Input from the fuel dial (voltage) can be confirmed in the monitor function. (Code No. 030: Fuel dial voltage) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Sensor power source defective If Service Code No. [E226] is displayed, troubleshoot the failure first.
2 Disconnection of wiring harness (Disconnection or defec- tive contact with connec- tor) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. E06 (male) Resistance value Between and 4.0 – 6.0 kΩ Between and 0.25 – 5.0 kΩ Between and 0.25 – 5.0 kΩ 3 Disconnection of wiring harness (Disconnection or defec- tive contact with connec- tor) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C01 (female) to J07 to E06 (female) Resistance value Below 1 Ω Wiring harness between C01 (female) and E06 (female) Resistance value Below 1 Ω Wiring harness between C01 (female) and E06 (female) Resistance value Below 1 Ω 4 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between C01 (female) and E06 (female) and grounding Resistance value Above 1 MΩ 5 Short-circuiting of wiring harness (Contact with 24 V cir- cuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting. Between wiring harness from C01 (female) to J07 to E06 (female) and grounding Voltage Below 1 V Between wiring harness between C01 (female) and E06 (female) and grounding Voltage Below 1 V 6 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.
C01 Resistance value Between and 4.5 – 5.5 V Between and 0.5 – 4.5 V