Komatsu — Service Code in Electrical System (Short-circuiting in battery relay)

TESTING AND ADJUSTING E315 Service Code in Electrical System (Short-circuiting in battery relay) E315 20-368 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Short-circuiting in battery relay (in governor • pump controller) — E315 D110KB Failure content • Abnormal current flew to the battery relay drive circuit, when power was supplied to the circuit. Response from controller • The controller turns OFF power to the battery drive circuit. • Even when the failure cause disappears, the relay does not return to normalcy, unless the engine start- ing switch is once turned OFF. Phenomenon occurring on machine • The engine does not stop.

Relative information • It can be confirmed in the monitor function how the battery relay works (ON or OFF). (Code No. 037: Controller output) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Battery relay defective (Internal failure) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Battery relay Continuity & Resistance value Between A21 (BR terminal) and A20 (E terminal) Continued Between A21 (BR terminal) and grounding Above 1 MΩ 2 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Between wiring harness from C03 (female) to D01 to J01 to A21 (BR terminal) and grounding Resistance value Above 1 MΩ 3 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.

C03 (female) Engine starting switch OFF Voltage Between and grounding ON → OFF 20 – 30 V (for 4 to 7 seconds)