Komatsu — Service Code in Electrical System (Step-out in governor motor)

TESTING AND ADJUSTING E316 Service Code in Electrical System (Step-out in governor motor) E316 20-370 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Step-out in governor motor (in governor • pump controller) — E316 DY10K4 Failure content • There is a big difference between signals from the potentiometer and the set values in the controller. Response from controller • The controller repeats the same controlling motions (step-out). • Even when the failure cause disappears, the governor motor does not return to normalcy, unless the engine starting switch is once turned OFF. Phenomenon occurring on machine • The engine rotation cannot be controlled.

• There is hunting in the rotation. • The engine does not stop. Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Fuel dial defective If Service Code [E308] is displayed, troubleshoot that failure first. 2 Governor potentiometer defective If Service Code [E306] is displayed, troubleshoot that failure first. 3 Governor motor defective (disconnection) If Service Code [E317] is displayed, troubleshoot that failure first. 4 Governor motor defective (short-circuiting) If Service Code [E318] is displayed, troubleshoot that failure first.

5 Governor lever adjustment improper Refer to the section of "Inspection and Adjustment - Special Func- tion of Monitor Panel" in this manual. 6 Engine fuel control system defective Refer to Engine Shop Manual. 7 Governor • pump controller defective As this is an internal failure, no troubleshooting can be carried out. (If there is none of the failures listed above, the controller is judged as defective)