TESTING AND ADJUSTING E317 Service Code in Electrical System (Disconnection in governor motor Phase A and B) E317 20-372 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Disconnection in governor motor Phase A and B (in governor • pump controller) E05 E317 DY10KA Failure content • No current flew to the governor motor, when power was supplied to the motor. Response from controller • None in particular. • If the failure cause disappears, the governor returns to normalcy. Phenomenon occurring on machine • The engine rotation drops to low idling. • There is hunting in the rotation • The engine does not stop. • The governor motor steps out.
Relative information • Operation of the governor motor (current) can be confirmed in the monitor function. (Code No. 033: Governor motor Phase A current, Code No. 034: Governor motor Phase B current) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Governor motor defec- tive (Internal disconnection) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
E11 (male) Resistance value Between and 2.5 – 7.5 Ω Between and 2.5 – 7.5 Ω 2 Disconnection of wiring harness (Disconnection or defec- tive contact with connec- tor) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between C03 (female) and E11 (female) Resistance value Below 1 Ω Wiring harness between C03 (female) and E11 (female) Resistance value Below 1 Ω Wiring harness between C03 (female) and E11 (female) Resistance value Below 1 Ω Wiring harness between C03 (female) and E11 (female) Resistance value Below 1 Ω 3 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. C03 (female) Resistance value Between and 2.5 – 7.5 Ω Between and 2.5 – 7.5 Ω