TESTING AND ADJUSTING E501 / E502 Service Code in Electrical System ("Model Selection" function not provided yet) E501 20-376 PC210/240-7K User Code Service Code Failure Code Failure phenomenon "Model Selection" function not provided yet (in governor • pump controller system) — E501 DA2AKM Failure content • Model Code is not inputted yet. Response from controller • Model data and rated load cannot be set. • Even when the failure cause disappears, Service Code does not return to normalcy, unless the engine starting switch is once turned OFF. Phenomenon occurring on machine • The excess load alarm does not work normally.
Relative information • Model names that the controller recognizes (figure) can be confirmed in the monitor function. (Code No. 150: Model Code) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Setting work not finished yet Refer to the section "Special Function of Monitor Panel" in this manual. ★There is a possibility that model selection operation has never been tried with that specific model from its delivery ex-works up to this mo- ment. 2 Governor • pump controller defective As this is an internal failure, no troubleshooting can be conducted.