TESTING AND ADJUSTING E-4 E-4 Engine does not stop PC210/240-7K 20-509 Failure information • The engine does not stop. Relative information • The Governor • pump controller drives the battery relay for the min. 4 seconds and max. 7 seconds from the moment the engine starting switch is turned OFF to the moment the engine completely stops. • It can be confirmed in the monitor function how the battery relay works (ON or OFF) (Code No. 037:
Controller output) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Battery relay fault If operating sound is heard from the battery relay contact, when turning the engine starting switch, the battery relay is judged as normal. • Starting switch OFF→ON→OFF 2 Assembled-type diode D01 fault (Internal disconnec- tion) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
D01 (male) Digital type circuit tester Continuity Between and Diode mode Continued 3 Disconnection of wir- ing harness (Disconnection or defective contact with connector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between C03 (female) and D01 (female) Resistance value Below 1 Ω Wiring harness from D01 (female) to J01 to battery relay BR terminal (A21) Resistance value Below 1 Ω Wiring harness between battery relay E terminal (A20) and grounding Resistance value Below 1 Ω 4 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. C03 Engine starting switch Voltage Between and grounding ON→OFF 20 – 30 V (for 4 to 7 seconds)