Komatsu — E-5 Auto-decelerator does not work

TESTING AND ADJUSTING E-5 E-5 Auto-decelerator does not work PC210/240-7K 20-511 Failure information • The auto-decelerator does not work. Relative information • Rotation of the auto-decelerator is set at 1,400 rpm. If the fuel dial is not set adjusting to this level, the auto-decelerator does not work. • Confirm the display on the monitor panel, when the engine is running. Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Boom RAISE signal fault If the display on the monitor panel is not normal, proceed to No. E-21 Troubleshooting. Monitoring code Item Normal display 019 Boom RAISE Lever operation: ON Lever NEUTRAL:

OFF 2 Boom LOWER sig- nal fault If the display on the monitor panel is not normal, proceed to No. E-22 Troubleshooting. Monitoring code Item Normal display 019 Boom LOWER Lever operation: ON Lever NEUTRAL: OFF 3 Arm DIGGING signal fault If the display on the monitor panel is not normal, proceed to No. E-23 Troubleshooting. Monitoring code Item Normal display 019 Arm DIGGING Lever operation: ON Lever NEUTRAL: OFF 4 Arm DUMPING signal fault If the display on the monitor panel is not normal, proceed to No. E-24 Troubleshooting. Monitoring code Item Normal display 019 Arm DUMPING Lever operation: ON Lever NEUTRAL:

OFF 5 Bucket DIGGING signal fault If the display on the monitor panel is not normal, proceed to No. E-26 Troubleshooting. Monitoring code Item Normal display 021 Bucket DIGGING Lever operation: ON Lever NEUTRAL: OFF 6 Bucket DUMPING signal fault If the display on the monitor panel is not normal, proceed to No. E-27 Troubleshooting. Monitoring code Item Normal display 021 Bucket DUMPING Lever operation: ON Lever NEUTRAL: OFF 7 Swing signal fault If the display on the monitor panel is not normal, proceed to No. E-28 Troubleshooting. Monitoring code Item Normal display 019 Swing Lever operation: ON Lever NEUTRAL:

OFF 8 Travel signal fault If the display on the monitor panel is not normal, proceed to No. E-29 Troubleshooting. Monitoring code Item Normal display 019 Travel Lever operation: ON Lever NEUTRAL: OFF 9 Attachment signal fault If the display on the monitor panel is not normal, proceed to No. E-30 Troubleshooting. Monitoring code Item Normal display 021 Service Lever operation: ON Lever NEUTRAL: OFF 10 Governor • pump controller defective As this is an internal failure, troubleshooting cannot be conducted. (If there is none of the causes listed in Item 1 through 9, the controller is judged as defective.