Komatsu — E-7 Preheater does not work

TESTING AND ADJUSTING E-7 E-7 Preheater does not work PC210/240-7K 20-513 Failure information (1) • Even if the preheater switch is turned to the PREHEAT position, the preheating monitor lamp does not light up. Relative information • Input of the preheating signal (ON or OFF) can be confirmed in the monitor function. (Code No. 045: Monitor input 1) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Engine starting switch fault If preheating does not occur (the heater is not warmed up), refer to Failure Phenome- non (2) below.

2 Disconnection of wir- ing harness (Disconnection or defective contact with connector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF posi- tion during the troubleshooting. Wiring harness between P02 (female) and J02 Resistance value Below 1 Ω 3 Monitor panel fault ★Turn the engine starting switch OFF for the preparations. P02 Engine starting switch Voltage Between and grounding OFF Below 1 V HEAT 20 – 30 V Failure information (2) • Even if the preheater switch is turned to the PREHEAT position, the preheater does not become warm.

Relative information • In low cooling water temperature (lower than 30°C), the governor • pump controller drives the heater relay for 100 seconds after the engine is started and automatically warms up the engine. Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Engine starting switch fault (Internal disconnec- tion) ★Turn the engine starting switch OFF for the preparations.

H15 (male) Engine starting switch Resistance value Between and OFF Above 1 MΩ HEAT Below 1 Ω 2 Heater relay fault (Internal disconnec- tion) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF posi- tion during the troubleshooting. Heater relay Continuity and resistance value Between coil terminal and grounding Continued Between contact terminals Above 1 MΩ 3 Electrical intake air heater (Internal disconnec- tion) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF posi- tion during the troubleshooting. Between heater terminals Normal if continuity is established.

4 Disconnection of wir- ing harness (Disconnection or defective contact with connector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF posi- tion during the troubleshooting. Wiring harness from H15 (female) to J02 to heater relay terminal (A25) Resistance value Below 1 Ω Wiring harness between battery relay M terminal (A22) and heater relay terminal Resistance value Below 1 Ω