TESTING AND ADJUSTING E-9 E-9 One-touch Power Max Switch does not work Electric Circuit Diagram for One-Touch Power Max. Switch PC210/240-7K 20-517 Failure information • The one-touch power max. switch does not work. Relative information • If the one touch-power max. switch is pressed while the engine is running, the symbol mark is displayed in the monitor panel. • Input from the one-touch power max. switch (left knob switch) can be confirmed in the monitor function. (Code No. 022: Switch input 1) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Fuse No.

9 fault If the fuse is blown, there is a big possibility that grounding fault occurred in the circuit. 2 ( t One-touch power max. switch fault Internal disconnec- ion) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. M23 (male) One-touch power max. switc h Resistance value Between and Release Above 1 MΩ Depress Below 1 Ω i 3 ( Disconnection of wir- ng harness Disconnection or defective contact with connector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Wiring harness between FB1-9 outlet and M23 (female) Resistance A value bove 1 MΩ Wiring harness between M23 (female) and C01 (female) Resistance A value bove 1 MΩ 4 ( Grounding fault of wiring harness Contact with grounding (GND) circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Between wiring harness between FB1-9 outlet and M23 (female) and grounding Resistance A value bove 1 MΩ Between wiring harness between M23 (female) and C01 (female) and grounding Resistance A value bove 1 MΩ 5 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. C01 One-touch power max. switc h Voltage Between and grounding Release Below 1 V Depress 20 – 30 V