Komatsu — E-12 Monitor panel displays contents irrelevant to the model

TESTING AND ADJUSTING E-11, E-12 E-11 Part of display on monitor panel is missing E-12 Monitor panel displays contents irrelevant to the model PC210/240-7K 20-519 Failure information • Part of the display in the monitor panel is missing. Relative information — Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Monitor panel LCD fault If all the LCD in the monitor panel light up (i.e. the screen becomes totally white) by the following switching operation, then the monitor panel is normal. • Switching operation:

[ ] + [ A ] (simultaneous switching operation) 2 Monitor panel defective As this is an internal failure, troubleshooting cannot be conducted. (If there is no prob- lem with the above switching operation, the monitor panel is judged as defective) Failure information • The monitor panels displays contents that have nothing to do with the model on which it is installed. Relative information — Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Model code signal fault (Internal failure) If the display on the monitor panel is normal, proceed to Service Code [E217].

Monitoring code Item Normal display 002 003 Controller model code 200 2 Monitor panel defective As this is an internal failure, troubleshooting cannot be conducted. (If there is no prob- lem with the above switching operation, the monitor panel is judged as defective)