TESTING AND ADJUSTING E-17 E-17 Swing lock monitor does not display correctly 20-524 PC210/240-7K Failure information • Though the swing lock switch was turned ON, the swing lock monitor does not light up. • Though the swing lock switch was turned OFF, the swing lock monitor lights up. Relative information • Input from the swing lock switch (ON or OFF) can be confirmed in the monitor function. (Code No. 049:
Monitor input 3) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Swing lock switch fault (Internal disconnec- tion or short-circuit- ing) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. X05 (female) Swing lock switch Resistance value Between and OFF Above 1 MΩ ON Below 1 Ω 2 Disconnection of wir- ing harness (Disconnection or defective contact with connector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from P02 (female) to J02 to X05 (male) Resistance value Below 1 Ω Wiring harness from X05 (male) to J05 to grounding Resistance value Below 1 Ω 3 Grounding fault of wiring harness (Contact with grounding (GND) circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Between wiring harness from P02 (female) to J02 to X05 (male) and grounding Resistance value Above 1 MΩ 4 Short-circuiting of wiring harness (Contact with 24 V circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting.
Between wiring harness from P02 (female) to J02 to X05 (male) and grounding Voltage Below 1 V 5 Monitor panel defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. P02 Swing lock switch Voltage Between and grounding OFF 20 – 30 V ON Below 1 V