Komatsu — E-28 "TRAVEL" is not correctly displayed in monitor function

TESTING AND ADJUSTING E-28 E-28 "TRAVEL" is not correctly displayed in monitor function 20-538 PC210/240-7K Failure information • "TRAVEL" is not correctly displayed in the monitor function (special function) on the monitor panel. Relative information — Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Travel PPC hydraulic switch fault (Internal disconnec- tion or short-circuit- ing) ★Turn the engine starting switch OFF for the preparations, and keep the engine running dur- ing the troubleshooting.

S30 (male) Travel control lever Resistance value Between and NEUTRAL Above 1 MΩ Forward or reverse Below 1 Ω 2 Disconnection of wir- ing harness (Disconnection or defective contact with connector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Wiring harness from C03 (female) to J01 to S30 (female) Resistance value Below 1 Ω Wiring harness from S30 (female) to J05 to grounding Resistance value Below 1 Ω 3 Grounding fault of wiring harness (Contact with grounding (GND) circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Wiring harness from C03 (female) to J01 to S30 (female) , or between wiring harness between C03 (female) and A43 (female) and grounding Resistance value Above 1 MΩ 4 Short-circuiting of wiring harness (Contact with 24 V circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. Wiring harness from C03 (female) to J01 to S30 (female) , or between wiring harness between C03 (female) and A43 (female) and grounding Voltage Below 1 V 5 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting.

C03 Travel control lever Voltage Between and grounding NEUTRAL 20 – 30 V Forward or backward Below 1 V