TESTING AND ADJUSTING E-29 E-29 "Travel Differential Pressure" is not correctly displayed in monitor function 20-540 PC210/240-7K Failure information • "Travel Differential Pressure" is not correctly displayed in the monitor function (special function) on the mon- itor panel. Relative information • When pressure difference is created between the right and left travel PPC circuits (in steering), the travel differential mechanism is turned ON.
Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Travel steering PPC hydraulic switch fault (Internal disconnec- tion or short-circuit- ing) ★Turn the engine starting switch OFF for the preparations, and keep the engine running dur- ing the troubleshooting. S31 (male) Travel control lever Resistance value Between and NEUTRAL Above 1 MΩ One side of right or left only Below 1 Ω 2 Disconnection of wir- ing harness (Disconnection or defective contact with connector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between C03 (female) and S31 (female) Resistance value Below 1 Ω Wiring harness from S31 (female) to J05 to grounding Resistance value Below 1 Ω 3 Grounding fault of wiring harness (Contact with grounding (GND) circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Between wiring harness between C03 (female) and S31 (female) and grounding Resistance value Above 1 MΩ 4 Short-circuiting of wiring harness (Contact with 24 V circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting.
Between wiring harness between C03 (female) and S31 (female) and grounding Voltage Below 1 V 5 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. C03 Travel control lever Voltage Between and grounding NEUTRAL 20 – 30 V One side of right or left only Below 1 V