Komatsu — E-30 "Service" is not correctly displayed in monitor function

TESTING AND ADJUSTING E-30 E-30 "Service" is not correctly displayed in monitor function 20-542 PC210/240-7K Failure information • "Service" is not correctly displayed in the monitor function (special function) on the monitor panel. Relative information — Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Service (front) PPC hydraulic switch fault (Internal disconnec- tion or short-circuit- ing) ★Turn the engine starting switch OFF for the preparations, and keep the engine running dur- ing the troubleshooting.

S10 (male) Service pedal Resistance value Between and NEUTRAL Above 1 MΩ Front Below 1 Ω 2 Service (rear) PPC hydraulic switch fault (Internal disconnec- tion or short-circuit- ing) ★Turn the engine starting switch OFF for the preparations, and keep the engine running dur- ing the troubleshooting. S11 (male) Service pedal Resistance value Between and NEUTRAL Above 1 MΩ Rear Below 1 Ω 3 Disconnection of wir- ing harness (Disconnection or defective contact with connector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Wiring harness between C03 (female) and S10 (female) , or wiring harness between C03 (female) and S11 (female) Resistance value Below 1 Ω Wiring harness between S10 (female) and grounding Resistance value Below 1 Ω 4 Grounding fault of wiring harness (Contact with grounding (GND) circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Wiring harness between C03 (female) and S10 (female) , or between wiring harness between C03 (female) and S11 (female) and grounding Resistance value Above 1 MΩ 5 Short-circuiting of wiring harness (Contact with 24 V circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. Wiring harness between C03 (female) and S10 (female) , or between wiring harness between C03 (female) and S11 (female) and grounding Voltage Below 1 V 6 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting.

C03 Service pedal Voltage Between and grounding NEUTRAL 20 – 30 V Front or rear Below 1 V