TESTING AND ADJUSTING H-9, H-10 H-9 Bucket moves slowly or lacks power H-10 Work equipment does not move in its single operation PC210/240-7K 20-611 Failure information • The bucket moves slowly, or lacks power. Relative information • Set the working mode at A mode for the troubleshooting. Presumed cause and stan- dard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Malfunctioning of right PPC valve (bucket circuit) ★Stop engine for preparations. Start troubleshooting at engine high idling.
Bucket lever PPC valve output pressure NEUTRAL 0{0} DIGGING or DUMPING Above 2.7 MPa {Above 28 kg/cm2} 2 Malfunctioning of bucket con- trol valve (spool) The spool in the bucket control valve is presumed to malfunction. Check the valve itself. 3 Malfunctioning of bucket con- trol valve (pressure compen- sation valve) The pressure compensation valve in the bucket control valve is presumed to malfunction. Check the valve itself. 4 Malfunctioning of bucket con- trol valve (safety and suction valves) or seal defective The safety and suction valves in the bucket control valve are presumed to malfunction, or the seal is suspected to be defective. Check those valves themselves.
5 Malfunction of LS shuttle valve (service valve) The LS shuttle valve in the service control valve is presumed to malfunction. Check the valve itself. 6 Bucket cylinder defective ★Stop engine for preparations. Start troubleshooting at engine high idling. Bucket lever Amount oil leakage from cylinder Digging relief 20 cc/min Failure information • The boom does not move when operated independently. • The arm does not move when operated independently. • The bucket does not move when operated independently. Relative information • Set the working mode at A mode for the troubleshooting.
Presumed cause and stan- dard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Malfunctioning of PPC valve ★Stop engine for preparations. Start troubleshooting at engine high idling. Work equipment control lever PPC valve output pressure NEUTRAL 0{0} Operation Above 2.7 MPa {Above 28 kg/cm2} 2 Malfunctioning of work equip- ment control valve (spool) The spool in the work equipment control valve is presumed to malfunction. Check the valve itself.