TESTING AND ADJUSTING H-12, H-13, H-14 H-12 Work equipment has big time lag H-13 Other work equipment moves when relieving single circuit H-14 One-touch power max. switch does not operate PC210/240-7K 20-613 Failure information • The work equipment has a big time lag. Relative information • Set the working mode at A mode for the troubleshooting. Presumed cause and stan- dard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Malfunctioning of LS-EPC valve ★Stop engine for preparations. Start troubleshooting at engine high idling. Travel speed Travel control lever LS-EPC valve output pressure Lo NEUTRAL Approx. 2.9 MPa {approx.
30 kg/cm2} Hi Operation 0{0} 2 Malfunctioning of control valve (regeneration valve) - with boom and arm only The regeneration valve in the control valve is presumed to malfunction. Check the valve itself. 3 Malfunctioning of control valves (safety & suction valve) The safety and suction valves of the control valve are presumed to malfunc- tion. Check those valves themselves directly. ★For the arm and boom, whether they are defective or not may well be de- termined by changing them for other safety and suction valves.
(Do not at- tempt to change them for the safety and suction valves for the boom LOWER and the lock valve, because each set pressure differs) 4 Malfunctioning of control valve (pressure compensation valve) The pressure compensation valve of the control valve is presumed to mal- function. Check the valve itself directly. Failure information • Other work equipment moves when relieving the single circuit of specific work equipment. Relative information • Set the working mode at A mode for the troubleshooting.
Presumed cause and stan- dard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Control valve (pressure com- pensation valve) seal defective The seal for pressure compression valve in the control valve is suspected to be defective. Check the seal itself. Failure information • The one-touch power max. switch does not operate. Relative information • Set the working mode at A mode for the troubleshooting. Presumed cause and stan- dard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Malfunctioning of 2-stage sole- noid valve ★Stop engine for preparations. Start troubleshooting at engine high idling.
Swing lock switch Solenoid valve output pressure OFF 0{0} ON 2.84 – 3.43 MPa {29 – 35kg/cm2} 2 Malfunctioning of main relief valve The main relief valve is presumed to malfunction. Check the valve itself.