TESTING AND ADJUSTING H-21 H-21 Travel speed does not shift, or it is too slow or fast. : The "Mi" mode is on the multi-monitor specification machine only. 20-618 PC210/240-7K Failure information • Travel speed does not shift, or it is either too fast or slow. Relative information • Set the working mode at A mode for the troubleshooting. Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Malfunctioning of LS-EPC valve ★Stop engine for preparations. Start troubleshooting at engine high idling.
Travel speed Travel control lever Monitoring [15] Lo Fine control (to the extent that the decelerator is released) 810 mA ( Mi) 470 mA Hi 0 mA ★Stop engine for preparations. Start troubleshooting at engine high idling. Travel speed Travel control lever LS-EPC valve output pressure Lo NEUTRAL Approx. 2.9 MPa {approx. 30 kg/cm2} Hi Operation 0 {0} 2 Malfunctioning of travel speed solenoid valve ★Stop engine for preparations. Start troubleshooting at engine high idling.
Travel speed Travel control lever LS-EPC valve output pressure Lo NEUTRAL 0 {0} Hi Operation 2.84 – 3.43 MPa {29 – 35 kg/cm2} 3 Malfunctioning of travel motor (speed shifting) The travel motor is presumed to malfunction when shifting speed. Check the speed shifting portion directly.