TESTING AND ADJUSTING H-23 H-23 Machine does not swing 20-620 PC210/240-7K Failure information (1) • The machine swings neither to the right nor to the left. Relative information • Set the working mode at A mode for the troubleshooting. Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Malfunctioning of swing park- ing brake solenoid valve ★Stop engine for preparations. Start troubleshooting at engine high idling. Swing Solenoid valve NEUTRAL 0 {0} Operation 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunctioning of swing motor (parking brake) The parking brake portion of the swing motor is presumed to malfunction.
Check it directly. 3 Improper adjustment or mal- functioning of swing motor (safety valve) ★Stop engine for preparations. Start troubleshooting at engine high idling. Swing lock switch Swing control lever Swing relief pressure ON Swing relief 28.9 – 32.9 MPa {295 – 335 kg/cm2} If the oil pressure does not return to normalcy even after the adjustment, the safety valve is presumed to malfunction, or suspected of an internal failure. Check the valve itself. 4 Swing motor defective ★Stop engine for preparations. Start troubleshooting at engine high idling.
Swing control lever Amount of oil leakage from swing motor Swing relief Below 10 ¬/min 5 Swing machinery defective The swing machinery is suspected of an internal failure. Check the inside of the swing machinery directly. ★A failure inside the swing machinery may well be determined by an abnormal noise from within, abnormal heat generated or metal dust or chips contained in the drained oil. Failure information (2) • The machine does not swing in one direction. Relative information • Set the working mode at A mode for the troubleshooting.
Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Malfunctioning of PPC valve ★Stop engine for preparations. Start troubleshooting at engine high idling. Left control lever PPC valve output pressure NEUTRAL 0 {0} Swing operation Above 2.7 MPa {Above 28 kg/cm2} 2 Malfunctioning of swing control valve (spool) The spool in the swing control valve is presumed to malfunction. Check the spool itself. 3 Swing motor (suction valve) seal defective The seal in the suction valve of the swing motor is suspected of defect. Check the seal itself.
★Whether the seal is defective or not may well be determined by swapping the right and left suction valves and watching if there is any change. 4 Swing motor (check valve) seal defective The seal in the check valve of the swing motor is suspected of defect. Check the seal itself. ★Whether the seal is defective or not may well be determined by swapping the right and left check valves and watching the result.