Komatsu — 16.6 OTHER TROUBLE

16. TROUBLESHOOTING 16. TROUBLESHOOTING 16.6.5 ELECTRONIC CONTROL SYSTEM If an error code is displayed on the machine monitor display (normally this displays the time), follow the self-diagnostic remedy table below. Machine monitor failure display Є: For details of handling the pump prolix switch and swing prolix switch, see “11.2 SWITCHES”. 2-100 Monitor display Failure mode Remedy E02 TVC valve system error When pump prolix switch is turned ON, normal operations become normal, but carry out inspection immediately. (ª) E03 Swing brake system error Turn swing prolix switch ON and release brake. When applying swing brake, operate swing lock switch manually.

In this case, carry out inspection immediately. (ª) E10 Abnormality in electronic governor system (engine stopped) Carry out inspection immediately. E11 Abnormality in electronic governor system (engine protection output down) Normal operations are possible, but carry out inspection immediately. E12 Abnormality in electronic governor system (normal operation) Normal operation is possible, but carry out inspection immediately. E13 Abnormality in electronic governor system (governor cut relay system) Normal operation is possible, but carry out inspection immediately.

E14 Abnormality in throttle (impossible to control engine speed) Move the machine to a safe posture, then carry out inspection immediately. E0E Abnormality in network (pump absorption torque reduced or engine stopped) If the engine can be run, move the machine to a safe posture, then carry out inspection immediately. If the engine is started and then stalls, turn the TVC prolix switch ON, move the machine to a safe posture, then carry out inspection immediately. If the engine is stopped, also carry out inspection immediately. CALL Operation cannot be continued Move machine to a safe posture, and carry out inspection immediately.

If no error code is displayed but work equipment or swing cannot be operated Carry out inspection immediately.