Komatsu — 24.4 CHECK BEFORE STARTING

24. SERVICE PROCEDURE 24. SERVICE PROCEDURE 24.4 CHECK BEFORE STARTING 24.4.1 CHECK COOLANT LEVEL, ADD WATER ¤ WARNING Do not open the radiator cap unless necessary. When check- ing the coolant, always check the radiator reserve tank when the engine is cold. Do not remove the cap when the radiator water is hot. Boiling water may spurt out. After the water temperature goes down, turn the cap slowly to release the pressure, then remove it. 1. Open cover 1 of the sub tank inspection window at the front of the radiator side (right side of machine) of the engine hood, and check that the coolant level is between the FULL and LOW lines on the two sub tanks 2 .

If the coolant level is low, add water through the water filler to sub tanks 2 to the FULL level. 2. After adding water, tighten the caps securely. 3. If the reserve tank becomes empty, first inspect for water leaks and then fill the radiator and the reserve tank with water. REMARK When adding water to the radiator, remove cover 3 , then loosen radiator cap 4 slowly. After checking that the pressure has been released, push in the cap, keep it pushed in, then loosen it further and remove it. Check that the level of the coolant is above the hatched portion in the diagram on the right. If the water level is low, add water through the water filler port.

After adding water, install radiator cap 4 . When operating in cold areas, see “14. COLD WEATHER OPERA- TION”. AE082160 24.4.2 CHECK OIL LEVEL IN ENGINE OIL PAN, ADD OIL ¤ WARNING The turbocharger (with safety cover) exhaust manifold is near dipstick G , so be careful not to touch it. 1. Open the cover at the fan side at the front of the engine room. 2. Remove dipstick G and wipe the oil off with a cloth. 3. Insert dipstick G fully in the oil filler pipe, then take it out again. 3-40