Komatsu — 24.7 EVERY 250 HOURS SERVICE

24. SERVICE PROCEDURE 24. SERVICE PROCEDURE 24.7.12 CHECK AIR CONDITIONER COMPRESSOR BELT TENSION, ADJUST (ONLY FOR MACHINES EQUIPPED WITH AIR CONDITIONER) Checking 1. Remove bolts 2 , 3 and 4 , then remove cover 1 . 2. The standard deflection for the drive belt is 10 – 15 mm (0.39 – 0.59 in) when pressed with a thumb [at approx. 58.8 N (approx. 6 kgf)] at a point midway between the drive pulley and air conditioner compressor pulley. Adjusting 1. Loosen belt adjustment nut 5 . 2. Loosen 4 bolts 6 . Bolts 6 are tightened from the rear of bracket (a). 3. Adjust the belt tension with bolt 7 . Adjust with bolt 7 as follows.

TIGHTEN bolt to INCREASE belt tension LOOSEN bolt to DECREASE belt tension 4. After adjusting the belt tension, tighten 4 bolts 6 . Check each pulley for breakage, wear of the V-groove, and wear of the V-belt. Check in particular that the V-belt does not contact the bottom of the V-groove. Replace the belt if it is elongated and can no longer be adjusted, or if it is cut or cracked. 5. Install cover 1 . 3-58