24. SERVICE PROCEDURE 24. SERVICE PROCEDURE 24.10.2 CHANGE OIL IN HYDRAULIC TANK, CLEAN STRAINER RELEASING PRESSURE FROM WORK EQUIPMENT CIRCUIT, SWING CIRCUIT, TRAVEL CIRCUIT ¤WARNING When removing the oil filler cap, turn it slowly to release the internal pressure, then remove it carefully. 1. Lower the work equipment to the ground in a stable flat place as shown in the diagram, then stop the engine. Set the lock lever to the FREE position. 2. After stopping the engine, move each work equipment control lever to the end of its travel within 5 to 6 seconds. Leave the starting switch ON. 3. Remove the cap of the hydraulic tank. 4. Start the engine, run it for approx.
10 seconds, then stop the engine again. When running the engine, do not raise the speed above 1000 rpm. Set the work equipment control levers to neutral. 5. After stopping the engine, move each work equipment control lever to the end of its travel within 5 to 6 seconds. Repeat Steps 4 to 5 three times. RELEASING PRESSURE IN ACCUMULATOR CIRCUIT Stop the engine, set lock lever 1 to the FREE position, then move each work equipment control lever 3 to 4 times to the end of its travel. After 1 minute passes, the pressure is relieved. Do not loosen the piping less than 1 minute after releasing pressure. 3-76