Komatsu — 11.14 HANDLING GREASE PUMP

11. EXPLANATION OF COMPONENTS 11. EXPLANATION OF COMPONENTS 11.11 FUSIBLE LINK If the starting motor will not rotate when the starting switch is turned ON, a possible cause is disconnection of wire-type fusible link 1 . Inspect the fusible link in battery box cover at right side of machine and, if necessary, replace it. REMARK A fusible link refers to the large-sized fuse wiring installed in the high current flow portion of the circuit to protect electrical compo- nents and wiring from burning, similarly to an ordinary fuse. 11.12 CONTROLLERS Engine controller 1 and pump controller 2 are provided.

NOTICE Never splash or spill water, mud or drink over the controllers as this may cause a fault. If a fault occurs in the controller, do not attempt repair, but consult your Komatsu distributor. 11.13 TOOL HOLDER (CLOTH BAG) This is inside the storage box inside the cover on the left side at the rear of the cab. 11.14 HANDLING GREASE PUMP This is stored inside the grease pump box on the right side of the chassis. 2-26