12. OPERATION 12. OPERATION CHECK OIL LEVEL IN HYDRAULIC TANK, ADD OIL ¤ WARNING When removing the oil filler cap, oil may spurt out, so turn the cap slowly to release the internal pressure before remov- ing the cap. If the oil is above the H level, stop the engine, wait for the hydraulic oil to cool down, then drain the excess oil from drain plug . When draining the oil, loosen bottom drain plug , then loosen the side drain plug and drain the oil. After draining the oil, tighten drain plugs and . 1.
If the work equipment is not in the condition shown in the diagram on the right, start the engine, run the engine at low speed, retract the arm and bucket cylinders, then lower the boom, set the bucket teeth in contact with the ground, and stop the engine. 2. Within 15 seconds after stopping the engine, move each control lever (for work equipment and travel) to the full stroke in all directions to release the internal pressure. 3. Check that the oil level is between the H and L line on oil level gauge G at the rear of the hydraulic tank. (It is possible to check from maintenance door 2 .) NOTICE Do not add oil if the level is above the H line.
This will damage the hydraulic equipment and cause the oil to spurt out. 4. If the oil is below the L line, add oil through oil filler F at the top of the hydraulic tank. NOTICE For details of the oil to use, see “20. USE OF FUEL, COOLANT AND LUBRICANTS ACCORDING TO AMBIENT TEMPERATURE”. REMARK The oil level will vary depending upon the oil temperature. Accordingly, use the following as a guide: Before operation: around L level (Oil temperature 10 to 30°C (50 to 86°F)) Normal operation: around H level (Oil temperature 50 to 80°C (122 to 176°F)) 2-35