Maintenance—Machine Hydraulic Oil IMPORTANT: Excavators are factory filled with Super EX 46HN extended life zinc-free hydraulic oil. DO NOT MIX ZINC-BASED AND ZINC-FREE OILS. Flushing system is required when changing from zinc-free to zinc-based oils. Contact authorized dealer for the flushing procedure. Avoid mixing different brands of oils. Oil manufacturers engineer their oils to meet certain specifications and requirements. Mixing different oils can degrade lubricant and machine performance. TX1007705 –19–20JUN06 Use oil viscosity based on the expected air temperature range during the period between oil changes. Low Temperature Operation Do not mix zinc-based and zinc-free oils.
A preferred ISO 32 hydraulic oil may be added to the machine for low temperature operations. Hydraulic system oil viscosity must be 32Cst at 40 ° C minimum and must not be operated when ambient temperature exceeds 30 ° C (86 ° F). When switching back to warm weather operation a preferred ISO46 hydraulic oil may be added to the machine. The hydraulic system oil viscosity must be 40Cst at 40 ° C minimum and must not be operated when ambient temperature exceeds 40 ° C (104 ° F). Seasonal Hydraulic Flushing Do not mix zinc-based and zinc-free oils. Two hydraulic tank flushes are required when changing hydraulic oils for seasonal operation.
Drain and refill tank with new oil (ISO32-cold, ISO46-warm.). Operate machine to mix oil in system. Drain and refill tank again. Check oil viscosity. Continued on next page DW90712,0000766 –19–07JUN07–1/2 3-1-9 010609 PN=108