Maintenance—Every 4000 Hours NOTE: The hydraulic oil filter and the pilot oil filter can be changed at this point in the procedure (See Section 3-8). 9. Install suction screen with cover. Suction screen must seal against outlet pipe in bottom of tank. If necessary, loosen nut (2) to adjust rod length. T135193 –UN–06NOV00 10. Close the ball valve and tighten the drain valve plug. Install bottom guard. 11. Add oil until it is between marks on sight glass. 450DLC—Specification Suction Screen Rod (1)—Length 945 mm +/- 1.5 mm ............................... 37.2 in. Suction Screen Rod Nut—Torque 14.5—19.5 .....................................
10.5—14.5 lb-ft Hydraulic Cover Cap Screw— Torque 50 ............................................................................................ 36.88 lb-ft 1—Suction Screen Rod 2—Suction Screen Rod Nut 650DLC—Specification Suction Screen Rod (1)—Length 1120 mm +/- 1.5 mm ............................. 44.1 in. Suction Screen Rod Nut—Torque 14.5—19.5 ..................................... 10.5—14.5 lb-ft Hydraulic Cover Cap Screw— Torque 50 ............................................................................................ 36.88 lb-ft 850DLC—Specification Suction Screen Rod (1)—Length 1220 mm +/- 1.5 mm ............................. 48.03 in.
Suction Screen Rod Nut—Torque 14.5—19.5 ..................................... 10.5—14.5 lb-ft Hydraulic Cover Cap Screw— Torque 50 ............................................................................................ 36.88 lb-ft 12. Install tank cap. 13. Bleed air from hydraulic system. (See Bleed Air From Hydraulic System in Section 3-7.) DW90712,0000023 –19–03JUL07–5/5 3-11-3 010609 PN=182