John Deere 450DLC, 650DLC, and 850DLC Excavators — Replacing Bucket Teeth

Miscellaneous—Machine JDLink In-Line Fuse (If Equipped) 1. Turn machine off. 2. Open battery compartment access door. 3. Remove cap screws (2) from cover to access the 7.5 Amp JDLink unswitched power n-line fuse (1) on the yellow wire. TX1014241A –UN–28OCT06 4. To deactivate the JDLink Machine Monitoring System, remove the unswitched power in-line fuse. 5. Install cover and cap screws. 6. Close access door. 1—JDLink Unswitched Power In-Line Fuse 2—Cap Screws (3 used) TX1024511A –UN–31MAY07 JDLink is a trademark of Deere & Company OUT4001,00002E1 –19–26JUN07–4/4 Replacing Bucket Teeth CAUTION: Guard against injury from flying pieces of metal; wear goggles or safety glasses. IMPORTANT:

Angle the drift toward the bucket to avoid damaging the rubber pin lock. T95784 –UN–10NOV88 1. Use a hammer and drift to drive out locking pin. NOTE: Alternate buckets may use different tooth assemblies. 2. Remove tooth. Continued on next page 04T,90,M16 –19–07SEP06–1/3 4-1-13 010609 PN=195