4-6-14 010609 PN=278 Miscellaneous—Operational Checkout Auto-Idle Circuit Check 1—Engine Speed Dial 2—Auto-Idle Switch 3—Power Mode Switch Turn engine speed dial (1) to fast idle (H) position. Turn power mode switch (3) to HP (high power) mode. Turn auto-idle switch (2) to A/I OFF. TX1000170 –UN–10NOV05 Place pilot shutoff lever to UNLOCKED position. Turn auto-idle switch (2) to A/I ON. LOOK/LISTEN: Does auto-idle indicator (2) illuminate? Does engine speed decrease after 4—6 seconds? Slowly actuate dig function. LOOK/LISTEN: Does engine speed return to fast idle? 1 2 3 4 5 6 A.I.
7777.7h F1 F2 F H F3 F4 E 17.3L/h C 8:01 1 2 3 4 5 6 7 8 9 0 F1 F2 F3 F4 TX1001140 –UN–04FEB06 1—Work Mode Indicator 2—Auto-Idle Indicator 3—Engine Coolant Temperature Gauge 4—F1 Function Button Indicator 5—Fuel Gauge 6—Hour Meter YES: Go to next check. NO: Check solenoid 10 A fuse (F4). – – –1/1 A.I. 7777.7h F1 F2 F H F3 F4 E 17.3L/h C 8:01