Procedure for Testing Batteries Batteries, Support, and Cables Visual Check 1. Check for damage such as cracked or broken case and electrolyte leakage. If damage is seen, replace battery. 2. Check electrolyte level. (See Check Battery Electrolyte Level in this group) If low, add distilled water to specified level and charge battery. 3. Check terminals for corrosion. If corroded, clean using a wire brush or battery post cleaner such as JT05838 Battery Post/Clamp Cleaner. 4. Check posts for looseness. If posts are loose, replace battery. Hydrometer Test 1. Check specific gravity with a hydrometer or battery tester such as JT05460 Coolant/Battery Tester. 2.
Record specific gravity reading for each cell. If high and low readings vary LESS than 0.050 and average specific gravity is between 1.225 and 1.280, battery is fully charged, go to LOAD TEST. If high and low readings vary LESS than 0.050 and average specific gravity is LESS than 1.225, charge battery and repeat test. If average specific gravity is still LESS than 1.225, replace both batteries. If high and low readings vary MORE than 0.050, charge battery and repeat test. If high and low readings still vary MORE than 0.050, replace both batteries. Batteries—Specification Hydrometer Test—Specific gravity 1.225—1.280 Fully charged ............................................................
Specific gravity Under 1.225 Discharged ................................................... 16 1671 6 TM1859 (14JUL04) 16-1671-6 700H Crawler Dozer Continued on next page CED,OUTX547,135 –19–20OCT98–1/2 071404 PN=348